Dr.ABE_Tube Ver2.22.02@Patch Installation Procedure 2014/11/8 Amada Co.,Ltd 2nd Software Development Dept. @***** Ver2.22.02 Support Details ***** afpc0945: On executing Auto Nesting, even though its not an incomplete part, there are cases where it displays message [Since Part is incomplete,could not be aligned. ] and doesnft do nesting. afpc0982: There are cases where A-axis rotates a little at the time of processing Projection Hole in SIM. afpc1191: The incomplete part of channel is not aligned correctly. afpc1197: The same sorting function as Load SDD was added to Save SDD. afpc1284: In Attribute Editor, Cutter joint is set to the outside of hole. afpc1285: Same as the above. afpc1287: Same as the above. afpc1379: When "Apply Slippage Offset" is ON, and if the outer loop where M00 is outputted is divided, M00 is outputted multiple times. afpc1530: If parts is flipped, a big arc will be created to the outer loop. afpc1792: In Setup Report , the hole on 0 deg face is also displayed in 180 deg face. afpc1888: There are cases where unwanted process is done to cut the Outer Loop after the Outer Loop is porcessed for Round Tube. afpc1990: When more than 2 parts are nested, after Auto Process on doing Hole division and changing the Process Sequence in Assign Editor, there are cases where the hole gets processed twice. afpc2133: When the Geometry Data has small entities (less than 0.001), geometry shape is not appropriate and and there are cases where assignment is not done. afpc2134: Although Cut-Off Process will not be divided, warning of "Divided Outer Loops are not subjected for Cut-Off Process." occurs, and outer loop is not assigned Cuts-Off Process. afpc2135: Even TubeDB has incorrect data, enabled to do take backup of data. afpc2136: An exception occurs in Rebuild of Parts In Prog of I/O. afpc2137: If TubeDBClearanceTool.exe is executed in the 64bit environment, an exception will occur. afpc2138: On saving to SDD data, there are cases where PRDDATA, NPDDATA folder is not created and data is not saved. @***** Ver2.22.01 Support Details ***** afpc0749: When Laser Material Name had words ofgABh, gBCh, gACh, gPIPEh, gMAINh, gESCh M102 was not outputted. afpc0750: On generating NC data with [Use Setup Sheet] in NC Output Conditionas ON, output with Middle/High speed was supported but M104Z0 was not outputted. afpc0751: On manually changing the Process Sequence and generated NC data for data having Empty Repo, it causes OT error in Simulation. afpc0752: In Nesting plan mode with multiple sheets(pipes), on outputting Setup Report for the specified sheet(pipe) [other than *] unless the Preview is done, Allignment information of Sheet1(Pipe1) is displayed as Allignment information of other selected sheet(pipe). ***** Cautions before Installation **** (1) This patch is a patch for the following versions. yVer2.22.00z yVer2.22.01z Please check that the following versions are installed before installing this patch. yVer2.22.00z yVer2.22.01z ****** Install Procedures ************ (1) Before installing please exit Dr.ABE_Tube in the computer when patch has to be installed. (2) Execute DrABE_Tube_V22202_Setup.exe (3) Launch Dr.ABE_Tube . @@@In the List, double click the VPSS mark by mouse on the right side ,and the display of "Version 2.22.02" confirms that the patch is installed correctly. This completes the Installation procedure. Thanks!